Installation/Operator's Manual #851062E
MODEL: 1600 / 1800
THE WOOD AND COAL FURNACE
SAFETY NOTICE: IF THIS FURNACE IS NOT PROPERLY INSTALLED, A HOUSE FIRE
MAY RESULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION REQUIREMENTS IN YOUR AREA.
UNITED STATES
STOVE COMPANY
Keeping America Warm Since 1869
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - STOVE COMPANY

Installation/Operator's Manual #851062EMODEL: 1600 / 1800THE WOOD AND COAL FURNACESAFETY NOTICE: IF THIS FURNACE IS NOT PROPERLY INSTALLED, A H

Page 2 - TABLE OF CONTENTS

DRAFTTUBECLAMPMOTORIZED NATURAL DRAFT 8MOTORIZED NATURAL DRAFTModels 1600 / 18001. Using (2) 1/4" x 1" bolts, lock washers and nuts,att

Page 3 - CHIMNEY REQUIREMENTS

DRAFT WIRING DIAGRAMALL WIRING MUSTBE DONE BY AQUALIFIEDELECTRICIANPredrilled holes are provided on the back of the furnacefor mounting the fan center

Page 4 - SMOKE PIPE INSTALLATION

10ALL WIRING MUST BE DONEBY A QUALIFIED ELECTRICIANLOADFANLINELOADLIMITLINEBREAK OFFJUMPER FORLOW VOLTAGEFAN "OFF"INDICATOR(100)FAN &q

Page 5 - INSTALLATION EXAMPLES

established, you are ready to load the furnace.CAUTION: To prevent flame and smoke spillage, the slidebaffle must be pulled out and the fuel door must

Page 6 - RETURN AIR IS VERY IMPORTANT

2. NEVER completely cover the live fire with fresh coal.Always leave a generous area of burning coal at the topof the fire and at the rear.3. Always k

Page 7 - ASSEMBLY INSTRUCTIONS

TROUBLE SHOOTING AND PROBLEM SOLVING1. Problem:Smoke puffs from furnaceSolution:A. Check chimney draft. Check for blocked chimneyor flue pipe. Use mir

Page 8

NOTE:1600 = 16 - FULL BRICK 1- HALF BRICK1800 = 22 - FULL BRICKPARTS LISTMODEL 1600/1800ITEM DESCRIPTION MODEL PART# 1 Left Side Front Ass

Page 9 - (PRE-INSTALLED AT FACTORY)

PARTS LISTMODEL 1600/180029353933273426304542444337384048464750494041ITEM DESCRIPTION PART#26 Top Safety Latch 2378627 Feed Door (Drilled) 6909128 Ash

Page 10 - MODEL 1600/1800

PARTS LISTMODELS 1600 / 1800Fan Limit Kit #C68399ITEM DESCRIPTION PART# 1 High Limit Control 80145 2 3-Speed Switch 80361 3 Plastic Knob C9267M 4

Page 11 - ELECTRICAL INSTALLATION

MOTORIZED NATURAL DRAFT PARTS LISTPRE-ASSEMBLED AT FACTORY(OPTIONAL KIT)3341191082211175126 17ITEM DESCRIPTION PART# 1 Draw Band 23888 2 1/4"

Page 12 - WIRING DIAGRAM

TABLE OF CONTENTS TCIntroduction ...

Page 13

ITEM DESCRIPTION PART# 1 Draft Blower 80422 2 Power Supply Cord C40899 3 FAD Bracket 69192 4 10-24 Kep Nut (3ea.) 83244 5 1/4-20 x 1" Bolt (

Page 14 - SHOULD NOT BE ALTERED

OPTIONAL ELECTRONIC CONTROL SYSTEM6597884123INSTALLATION INSTRUCTIONS1. Remove top of furnace.2. Attach heat sensor "L" bracket to pins loca

Page 15 - 13

20BLOWERCONTROL CENTERDRAFTRECEPTACLEHEAT SENSORTHERMOSTATNOTE: DAMAGE TO HEAT SENSOR WILL PREVENTUNIT FROM OPERATING PROPERLY.CAUTIONUSE NO MORE

Page 16 - PARTS LIST

3-SPEED BLOWER ADJUSTMENTThe control center is equipped with three adjustments thatallow you to select the temperature at which the blower startsopera

Page 17

WIRING DIAGRAMS FOR ELECTRONIC CONTROL SYSTEMFor Model 1600 / 1800STANDARD WIRE(Diagram #1)HEATING OPTION(Diagram #2)POWERSUPPLYELECTRONICCONTROL BOA

Page 18

WIRING DIAGRAMSFor Model 1600 / 1800BLUEWHITEBLACKREDBLOWER MOTORPOWERSUPPLYAUX.FANRWYGTHERMOSTATPLENUMHEATSENSORDRAFT FANORMOTORIZEDDRAFTA/CCONTACTOR

Page 19

INSTALLATION OF OPTIONAL EQUIPMENTINSTALLING DOMESTIC HOT WATER COIL1. Remove access panel at rear of enclosure.2. With a utility knife cut out the se

Page 20 - FORCED AIR DRAFT PARTS LIST

25INSTALLING BACK DRAFT DAMPERThe back draft damper may be installed in either a vertical or horizontal section of the hot air duct. It should be

Page 21

Notched both sidesfor Blower Wire.Insert the filter and slide the filter cap into place.The 18" square air intake can be fitted with a collarto a

Page 22 - WIRING INSTRUCTIONS

OF EITHER SIDE AT THIS POINT.4. Attach filter holders to sides of enclosure with sheet metalscrews.5. Position filter fillerbetween side filterholders

Page 23 - 3-SPEED BLOWER ADJUSTMENT

INTRODUCTIONThank you for your purchase of a U.S. Stove Woodburningfurnace. Your decision to buy a Hotblast Furnace wasundoubtedly reached after much

Page 26

HOW TO ORDER REPAIR PARTSTHIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROMTHE HEATER, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY

Page 27 - INSTALLING BACK DRAFT DAMPER

always follow the chimney manufacturers instructions.NOTE: Type of chimney: Class A All-Fuel also referred to asLow-Heat appliance type chimney per Un

Page 28

When using a Class A or double wall flue pipe connection,follow the manufacturer's instructions.When constructing a single wall smoke pipe, the f

Page 29 - DELUXE FILTER BOX

INSTALLATION NO.1With this installation, a back draft damper is inserted into theheat run before the plenum of the existing furnace to preventair from

Page 30

furnace, a gas water heater, or gas furnace. The fumes couldthen be distributed throughout the house.COMBUSTION AIRAll fires need air (specifically ox

Page 31

DOOR HANDLE INSTALLATIONInsert door handle into door. From rear side of door place1/2" washer over threaded part of door handle. Then attach1/2&q

Page 32 - HOW TO ORDER REPAIR PARTS

BRICK INSTALLATION(PRE-INSTALLED AT FACTORY)NOTE: Prior to operation, be sure to remove brickretaining strips.FIREBOX:The firebrick must be inserted o